Our DC Load Banks would typically be packaged
in one of our PortaBank™ or MegaBank™
enclosures. Other enclosures would be used if
necessary. All of our load banks are fully operational,
extremely durable, lightweight and
portable so that they can easily be moved from
site to site to handle all of your load requirements.
Our products are designed and manufactured
to be able to withstand vibration,
shock, tough working conditions and high
temperatures! Mosebach’s resistors are the
toughest and the best on the load bank market!
Testing Voltages: DC load banks can be
designed to test all DC voltages (please contact
us with your exact specifications and requirements
i.e. V, A, kW and minimum load step).
Enclosure & Portability: Typically our enclosures
are made of heavy-duty, electro-statically
powder coated, scratch resistant,
sheet metal with casters or wheels and lifting
provisions for easy lifting and maneuvering. Air
inlet and outlet openings are protected by
expanded metal screens. Heat will typically be
discharged horizontally. Additional enclosure
options are available.
Dimensions: Will vary depending on the model.
Controls: Standard controls, mounted on the load bank include the following:
- Two digital meters with LED display capable
of measuring DC volts and DC amperes.
- One master ON/OFF 22mm switch.
- One blower ON/OFF 22mm switch.
- One voltage selection 22mm switch.
- Multiple ON/OFF toggle switches for each
load step for individual control.
- Air flow indicator lamps.
- Over temperature indicator lamp.
- Test jacks (+) and (-).
Resistors: SlimLine™ resistors consisting of a
stamped stainless steel plate held in place with
mica insulators. 2-year warranty.
Rating: Continuous duty.
Control Power: 120V, single phase, 50/60Hz is
typically taken from the fan power.
Cooling: Mosebach’s resistive elements are
cooled by integrally-mounted, low-noise highvolume
blowers. The blower power is typically
externally supplied by client.
Load Connections: CAM-lock type, color coded
rated for 400A each; (+) and (–).
Contactors: Heavy duty DC Contactors will be
used to break the (+) side.
Safety Features: Branch circuit fusing, an airflow
pressure sensor, an over temperature
sensor and ground lug.
OPTIONS AVAILABLE FOR PURCHASE:
Electrical:
- Various step resolutions
- Remote and PLC-control capabilities are
available
- Mating Female CAM-Lock type connections
- Cable Set with mating female CAM-locks
type connections
- Step down transformer for control power
[when blower voltage is not 120V, 1 phase]
- 2 pin aircraft connector(s) (28V or 270V)
Mechanical [varies by model]:
- Forklift channels
- Protective vinyl cover
- Weather rated enclosure
- Support brackets for stationary mounting
Warranty: One year for material and workmanship.
Two full years for resistor elements!
DC LOAD BANK MODELS:
Model Number |
kW |
Voltage(s) (DC) |
Amperes |
Min. Load Resolution |
Dimensions
(L, W, H) |
PB1F2448DCMV |
24 |
24/48 |
500 |
5A |
21 ”x 21” x 21” |
VPB1F2448DCMV |
24 |
24/48 |
500 |
variable |
21 ”x 21” x 21” |
VPB2F60120DCMV |
60 |
24/48/120 |
500 |
variable |
21”x 21” x 21” |
PB1F24120DCMV |
24 |
24/48/120 |
200 |
5A |
21 ”x 21” x 21” |
PB1F1428DC |
14 |
28 |
500 |
5A |
21 ”x 21” x 21” |
PB1F2828DC |
28 |
28 |
1,000 |
5A |
21 ”x 21” x 21” |
PB1F2448DC |
24 |
48 |
500 |
5A |
21 ”x 21” x 21” |
PB2F4848DC |
48 |
48 |
1,000 |
5A |
34” x 21” x 19” |
PBH31.87560DC |
31.875 |
60 |
531.25 |
2A |
54” x 29" x 33" |
CPBH9050DCMV |
90 |
50/100 |
1,800 |
100A |
54” x 29" x 33" |
PB1F50100DC |
50 |
100 |
500 |
5A |
21” x 21" x 21" |
PBH201.5105DC |
201.5 |
105 |
1,919 |
1A |
54” x 29" x 33" |
PB1F37.5150DC |
37.5 |
150 |
250 |
5A |
21” x 21" x 21" |
PB2F84240DCMV |
84 |
120/240 |
350 |
5A |
34” x 21” x 19" |
PB1F36240DCMV |
36 |
120/240 |
150 |
5A |
21” x 21" x 21" |
PB2F98280DCMV |
98 |
140/280 |
350 |
5A |
34” x 21” x 19” |
PB3F120240DC* |
120 |
240 |
500 |
5A |
21” x 21” x 48” |
MB400250DCMV |
400 |
250 |
1,600 |
5A |
72” x 31” x 56” |
Model Number |
kW |
Voltage(s) (DC) |
Amperes |
Min. Load Resolution |
Dimensions
(L, W, H) |
PB2F81270DC |
81 |
270 |
300 |
5A |
34” x 21” x 19” |
SRMLB2X2375DC |
4 |
375 |
10.66 |
5.33A |
22” x 19” x 10.5” |
PBH142400DC |
142 |
400 |
355 |
5A |
54” x 29” x 33” |
SPBH120480DC |
120 |
480 |
250 |
50A |
54” x 37” x 32” |
PBH192480DCMV |
192 |
480 |
400 |
100A |
54” x 29” x 33” |
PB2F90600DC |
90 |
600 |
150 |
5A |
34” x 21” x 19” |
SPBH240600DC |
240 |
600 |
400 |
5A |
54” x 37” x 32” |
PBH255600DC |
255 |
600 |
425 |
5A |
54” x 29” x 33” |
PB2F70700DC |
70 |
700 |
100 |
5A |
21” x 21” x 37” |
PBX273700DC* |
273 |
700 |
390 |
10A |
36” x 22” x 48” |
PB3F47.5750DC* |
47.5 |
750 |
63.3 |
3.33A |
21” x 21” x 48” |
PBH150750DC |
150 |
750 |
200 |
5A |
54” x 29” x 33” |
PBH150600DCMV |
150 |
50/100/200 300/400 500/600 |
250 |
50A |
54” x 29” x 33” |
MB540600DCMV |
540 |
50/100/200 300/400 500/600 |
900 |
100A |
72” x 31” x 56” |
PBH28848050DC |
288 |
120/240/288 360/384/480 |
600 |
100A |
54” x 29” x 33” |
MBX12501000DCMV |
1,250 |
300/600/1000 |
1,250 |
5A |
109” x 52” x 58” |
We can design and build almost any load bank to fit your needs. Please contact us with your specifications! |
Other Load Bank types available: Rad-mounted, locomotive testing, stationary and resistive/reactive. Please contact us for all AC applications.
|
|